. idc1 : agilent 4284a lcr meter + agilent 42841a bias current sourc e . idc2 : yokogawa dr130 hybrid recorder + agilent 6692a dc power suppl y test condition -40 ~ +85 (including self-generated heat) . l(frequency , voltage) : f=100 (khz) , v=0.5 (v) . idc1(the saturation current) : l 30% reduction from initial l value . idc2(the temperature rise): t= 30 typical at rated dc current rated dc current(idc) : the value of idc1 or idc2 , whichever is smaller operating temperature range test equipments packing style . l : agilent e4980a precision lcr mete r t : taping b : bulk . rdc : hioki 3540 m ? hitester 1.25 lpf1040t-221m 220 0.756 0.92 0.70 lpf1040t-101m 100 0.304 1.35 1.60 lpf1040t-680m 68 0.213 1.50 1.42 lpf1040t-470m 47 0.150 1.90 2.50 lpf1040t-330m 33 0.093 2.40 2.20 lpf1040t-220m 22 0.073 2.70 15 0.050 3.60 3.10 0.027 4.80 4.80 lpf1040t-100m 10 0.035 4.40 3.80 0.016 5.80 5.20 lpf1040t-6r8n 6.8 0.025 5.50 5.00 0.010 8.50 6.50 LPF1040T-3R7N 3.7 0.013 7.00 5.50 lpf1040t-1r8n 1.8 30 100 lpf1040t-4r7n 4.7 lpf1040t-8r2m 8.2 20 lpf1040t-150m rated dc current(a) code l (uh) tol. (%) f (khz) rdc (max.) idc1 (max.) idc2 (typ.) ordering inductance freq. dc resistance( ? ) electrical characteristics lpf1040 series smd shielded type shape & dimensions / recommended solder land pattern (dimensions in mm) http://www.abco.co.kr 10.3 max 10.00.3 10.30.3 3.80.2 100 7.0 1.55 3.0 2.2 6.5 3.6
|